[F106_1] ADI-HDD error: HDD type detection error

Classification
Other service call
Check Item
Setting
HDD

[F106_2] ADI-HDD error: ADI encryption key download operation error

Classification
Other service call
Check Item
Setting
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
ADI-HDD error: HDD type detection fails.
If the error is not recovered after rebooting the equipment
or no abnormality is found on any check items for the HDD,
reinstall the master data (HD Data).
Connector check
Harness check
Perform the bad sector check (08-9072).
If the check result is OK, recover the data in the HDD. If
the check result fails, replace the HDD.
Check that either the ADI-HDD or SATA-HDD (normal
type) is mounted.
(1)
Start the equipment in the 4C mode: [4] + [C] +
[POWER]
(2)
Check the type of the HDD shown on the top left of
the control panel display "Current HDD type".
Normal status: ADI-HDD or SATA-HDD
Abnormal status: Unknown HDD
If "Unknown HDD" is displayed, reinstall the master data
(HD Data).
ADI-HDD error: Downloading of or consistency check for ADI-
HDD encryption key fails.
Checking of ADI-HDD encryption key status
(1)
Start the equipment in the 3C mode: [3] + [C] +
[POWER]
(2)
The authentication menu is displayed. Press [OK].
(Not required in the default setting)
(3)
Select "5. Key Backup Restore" and then press the
[START] button.
(4)
Check the status of the ADI-HDD encryption key on
the Key Backup Restore Mode menu.
(5)
After the operation is completed, shut down the
equipment by pressing the [POWER] button.
In case both the SRAM ADIKey and FROM ADIKey
status are OK
Reinstall the system ROM data (OS Data).
In case either the SRAM ADIKey or FROM ADIKey
status is other than OK
Restore the ADI-HDD encryption key.
In case both of the SRAM ADIKey or FROM ADIKey
status are other than OK
Reinstall the master data (HD Data).
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved