Counter indicating the current number of prints and driving time
08-6194 : Current value of PM counter [process unit (K)]
08-6195 : Current value of PM time counter [process unit (K)]
08-5568 : Current value of PM counter [developer material (K)]
08-5569 : Current value of PM time counter [developer material (K)]
08-5576 : Current value of PM counter [parts other than the PM parts of the process unit]
08-5577 : Current value of PM time counter [parts other than the PM parts of the process unit]

Setting value which determines the display conditions

08-6198 : Switching of output pages/driving counts at PM [process unit (K)]
08-5581 : Switching of output pages/driving counts at PM [developer material (K)]
08-5585 : Switching of output pages/driving counts at PM [parts other than the PM parts of the
process unit]
For example, you can set the conditions of the PM display of the [process unit (K)] as follows.
PM display by specifying the
number of prints
PM display by specifying the
driving time
PM display by the earlier one:
when the number of prints or the
driving time reaches the set value
If the value of 08-9891 (Warning message on the touch panel when PM time has come) is set to "0: No
warning notification", the PM display is not performed regardless of the settings above. (Default value is
"1: Display warning notification")
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
PREVENTIVE MAINTENANCE (PM)
1. Key in "0" for 08-6198 (Switching of output pages/driving
counts at PM [process unit (K)]).
2. Key in the value of the number of prints for the PM display
other than "0" for 08-6190 (Setting value of PM counter
[process unit (K)]).
1. Key in "1" for 08-6198 (Switching of output pages/driving
counts at PM [process unit (K)]).
2. Key in the value of the driving time for the PM display other
than "0" for 08-6191 (Setting value of PM time counter [process
unit (K)]).
1. Key in "2" for 08-6198 (Switching of output pages/driving
counts at PM [process unit (K)]).
2. Key in the value of the number of sheets for the PM display
other than "0" for 08-6190 (Setting value of PM counter
[process unit (K)]).
3. Key in the value of the driving time other than "0" for 08-6191
(Setting value of PM time counter [process unit (K)]).