After the update is completed properly, the LED on the download jig blinks (at an interval of
approx. 1 sec.).
The LED starts blinking approx. 50 sec. after the update starts. It is assumed that the update has
failed if it does not start blinking even though 2 min. has passed. In this case, shut down the
equipment and check the following items. Then clear the problems and restart updating from the
beginning.
Is the download jig connected properly?
Is the ROM installed to the download jig properly?
Is the updating data written on the ROM of the download jig properly?
Do the download jig, RADF and the equipment operate properly?
(8)
Press the [ON/OFF] button on the control panel to shut down the equipment and turn the power
OFF using the main power switch.
Remove the download jig and install the RADF rear cover.
(9)
Close the front cover.
[B] Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
were overwritten properly.
 P. 11-81 "11.7 Confirmation of the updated data"
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
11 - 49
FIRMWARE UPDATING