11.5.4

Finisher firmware (MJ-1033)

(1)
Install the ROM [2] to the download jig (K-PWA-DLM-320) [1].
Make sure that the type of the ROM and the installation direction are correct.
(2)
Turn OFF the power of the connected equipment, and then release the Finisher from the
equipment.
(3)
Take off the rear cover of the Finisher.
(Refer to "MJ-1033/6008 Service Manual P4-4 [E] Rear cover")
* After taking off the rear cover of the Finisher, be sure to connect the finisher interface cable to
the equipment.
(4)
Connect the download jig [1] to the jig connector (CN5) [6] on the finisher control PC board (FIN).
(5)
Turn the power ON with the main power switch while pressing the digital keys [0] and [8]
simultaneously.
Updating starts and the LED on the download jig lights.
(6)
When the update is completed normally, the LED on the download jig starts blinking slowly.
The LED starts blinking after approx. 10 seconds have passed since the update had started.
When the LED does not blink even after 1 minute or more has passed or when it is blinking too
fast, this means the update has failed. In this case, turn the power OFF and check items below.
After checking the item, solve the problem and restart the update.
Is the downloading jig connected properly?
Is the ROM attached to the downloading jig properly?
Have the update data been written correctly to the ROM on the jig?
Is the download jig or the equipment damaged?
(7)
Turn the power OFF and then remove the download jig.
(8)
Reinstall the rear cover of the Finisher.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
FIRMWARE UPDATING
[6]
[1]
Fig.11-43
11 - 52