[F350] Slg Board Abnormality (E-Studio206L/256/306/356/456/506); [F400] Sys/Hdd Cooling Fan Abnormality - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

Replacement part
SRAM on the SYS board

[F350] SLG board abnormality (e-STUDIO206L/256/306/356/456/506)

Classification
Circuit related service call
Check Item
SLG board
Combination of the firmware
version
Replacement part
SLG board

[F400] SYS/HDD cooling fan abnormality

Classification
Circuit related service call
Check Item
SYS/HDD cooling fan
SYS board
Replacement part
SYS board
SYS/HDD cooling fan
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
SLG board abnormality
Board check
Check the combination of the firmware version of the system
ROM, engine ROM, and scanner ROM.
Reinstall the scanner ROM firmware.
SYS/HDD cooling fan abnormality
Check if the fan is rotating properly. If not, check if any foreign
object is adhered.
Check the connector (*1) and relay connector.
*1: CN112: e-STUDIO206L/256/306/356/456/506
CN105: e-STUDIO207L/257/307/357/457/507