[ 2 ] Resetting procedure
The setting values which are set in  P. 6-101 "[ 1 ] Adjusting procedure"can be reset with the
following steps.
(1)
Turn OFF the power of the equipment.
(2)
Remove 1 screw and take off the board access cover.
(3)
Set the SW1 on the Finisher control board as shown in the figures below.
(4)
Turn ON the power of the equipment while pressing the [0] button and the [8] button
simultaneously.
(5)
Press [Button1] 11 times, press [Button2] once, press [Button1] 11 times, and then press
[Button2] once.
(6)
Press [Button1] and [Button2] simultaneously.
(7)
Turn OFF the power of the equipment.
(8)
Turn OFF all bits of SW1 on the Finisher control board as shown below.
(9)
Install the board access cover with 1 screw.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
[1]
Fig.6-120
ON SW1
1
2
3
4
Fig.6-121
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
6 - 107
SW1
ON
1
2
3
4
SW1
ON SW1
1
2
3
4