4.14.8
Reverse sensor (S23) (only installed for e-STUDIO356/456/506 /
357/457/507)
(1)
Take off the reverse unit.
( P. 4-124 "4.14.1 Reverse unit (only
installed for e-STUDIO356/456/506 / 357/
457/507)")
(2)
Remove 3 screws and take off the plate.
Notes:
When installing, engage the slit of the
reverse gate solenoid and the lever of the
gate.
(3)
Disconnect 1 connector, release the latch,
and take off the reverse sensor.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Plate
Fig. 4-372
Reverse sensor
Connector
Fig. 4-373
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
4 - 131
Reverse unit
Lever
Slit