Disconnect 1 connector and remove 4
screws. Take off the lens unit.
Notes:
1. When installing, be sure that the harness
of the APS sensor comes over the lens
unit.
2 See chapter 6.9.2 for the adjustment
procedure.
3 Do not touch 8 screws shown with the
arrows when replacing the lens unit.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
DISASSEMBLY AND REPLACEMENT
Lens unit
Harness
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
4 - 32
Fig. 4-93
Harness
Fig. 4-94
Fig. 4-95