[2C20] System Management Module Access Abnormality; [2C21] Job Control Module Access Abnormality; [2C22] Job Control Module Access Abnormality; [2C30] Directory Creation Failure - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[2C20] System management module access abnormality

[2C21] Job control module access abnormality

[2C22] Job control module access abnormality

Classification
E-mail related error
Check item
Setting
Replace parts
SYS board

[2C30] Directory creation failure

[2C31] File creation failure
[2C33] File access failure
Classification
E-mail related error
Check item
Setting
[2C40] Image conversion abnormality
[2C62] Memory acquiring failure
Classification
E-mail related error
Check item
Setting
Replace parts
Main memory
[2C43] Encryption error
Classification
E-mail related error
Check item
Setting
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Turn the power OFF and then back ON. Perform the job in
error again.
Check that there is no other job in progress, and format
the HDD with [5] + [C] + [START].
If the recovery is still not completed, replace the SYS
board.
Check if the access privilege to the storage directory is
writable.
Check if the server or local disk has a sufficient space in
disk capacity.
Turn the power OFF and then back ON. Perform the job in
error again.
Replace the main memory and perform the job again.
Turn the power OFF and then back ON. Perform the job in
error again.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
8 - 233
Error item
Measures
Remarks
Error item
Measures
Error item
Measures
Remarks
Error item
Measures
ERROR CODE AND TROUBLESHOOTING