Fuser Unit Status Detection Mode - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

7.6

Fuser Unit Status Detection Mode

7.6.1
General description
As this equipment complies with the ERU provisions (Easy Replacement Unit), the fuser unit can be
removed or reinstalled without any problem.
The fuse (service part) for detection of a new fuser unit can be installed in the unit. The circuit
determining the fuser unit status judges whether the fuser unit is new or used by detecting the status of
the fuse. In addition, when the circuit detects that a new fuser unit is connected, it supplies current to
blow out the fuse to clear the fuser-related life counters.
Notes:
If only the supply parts in the fuser unit are to be replaced at PM, perform life counter clearing for
each one in the PM support mode as described in this chapter.
7.6.2
Operational flow
(1)
When replacing supply parts or the fuser unit at PM, install a new fuse in it.
Notes:
If a fuser unit with an installed fuse is selected, replace that the fuse with a new one because it
will have been blown out.
(2)
Install the fuser unit in the equipment.
(3)
Turn the power ON. If the fuser unit is then judged determined to be new, the fuser-related life
counters are automatically cleared.
7.6.3
Counters to be cleared
08-6346: Fuser roller counter
08-6350: Pressure roller counter
08-6368: Fuser roller separation finger counter
08-6225: Number of output pages (Thick paper 1)
08-6226: Number of output pages (Thick paper 2)
08-6227: Number of output pages (Thick paper 3)
08-6228: Number of output pages (OHP film)
08-6247: Counter for envelopes
08-6244: Counter for tab paper
7.6.4
Precautions
When the counters are not cleared, though the fuser unit is new, check that the value of the code
08-4549 is set at "0". If the value is "1", change it to "0", turn the power OFF and then back ON.
Then check the counter values again.
08-4549 (Detection setting of new or old fuser unit) 0: Enabled, 1: Disabled
When the fuse is not blown out, though the fuser unit is new, a C4C0 error occurs. In this case,
replace the fuse and turn the power OFF and then back ON, or remove the fuse and clear the
counters in the PM support mode.