[Cc53] Punch Waste Full Sensors (S41 And S42) Abnormality; [Cc54] Abnormality Of Paper Detection Sensors (S24 And S25) - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[CC53] Punch waste full sensors (S41 and S42) abnormality

MJ-1033
Error
Punch waste full sensor
Probable cause
Punch waste full sensors (S41 and
S42) abnormality
Faulty cables and connectors
Hole punch control PC board (HP)
abnormality

[CC54] Abnormality of paper detection sensors (S24 and S25)

MJ-1032
Error
Paper detection sensor (S24/S25)
adjustment error
Probable cause
Paper detection sensors (S24 and
S25) abnormality
Faulty cables and connectors
Hole punch control PC board (HP)
abnormality
[CC54] Abnormality of trailing edge detection sensors (S39 and S40) and horizontal registration
detection sensors (S39 and S40)
MJ-1033
Error
Trailing edge detection sensor
Horizontal registration detection
sensor
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Timing of detection
After the sensor output adjustment, the input value is lower than
1.2V against the output value of 2.8V, or the input value is
higher than 1.5V against the output value of 0.1V.
Checking and measures
Measure the voltage on TP49 on the hole punch control PC
board (HP). Then check that the measured voltage is 1V or
lower when not shielded and 2.5V or higher when shielded. If
the voltage does not fall within the range mentioned, replace a
couple of PC boards on either the light-receiving side or the
light-emitting side.
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connector. (Hole punch control PC board (HP): CN5)
If the error still occurs after replacing the sensors and the
connectors, exchange the hole punch control PC board (HP).
Timing of detection
The adjustment of the paper detection sensors (S24 and S25) has
been failed.
Checking and measures
Measure the voltage on pin CN6.8 on the hole punch control PC board
(HP). Then check that the measured voltage is 3.0V or higher when
not shielded and 1.2V or lower when shielded. If the voltage does not
fall within the range mentioned, replace a couple of PC boards on
either the light-receiving side or the light-emitting side.
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector. (Hole
punch control PC board (HP): CN4, CN6)
If the error still occurs after replacing the sensors and the connectors,
exchange the hole punch control PC board (HP).
Timing of detection
After the sensor output adjustment, the input value is lower than
3.2V against the output value of 2.8V, or the input value is
higher than 3.5V against the output value of 0.1V.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved