(05) adjustment value/(08) setting value difference list
05 DIFFERENCE LIST
xx-xx-xx xx:xx
CODE
* 2400
The function in which the 05/08 setting value differences between the factory default and the current
value can be printed or output with a CSV file.
The list of differences between the current and the backed-up values of the (05) adjustment and the
(08) setting values is output. "*" is marked on the left side of the code if there is a difference, and "+"
is marked on the left side of the code if there is no backed-up value.
Notes:
Back-up data of the factory default are automatically created when the automatic gamma
adjustment of the easy set-up mode has been completed during the unpacking and setting up
of the equipment. The back-up file is retained even if the firmware is upgraded. However, the
file is deleted when 3C-3 (Format HDD) is performed or HDD/SSD is replaced.
A back-up file does not exist for equipment to which the easy set-up mode has been
performed before this function is applied.
When the easy set-up mode is restarted while a specified value such as 3 is set for 08-9022
(Production process management status for easy setup), the back-up file stored during
unpacking and setting up after the completion of the automatic gamma adjustment is deleted,
and another file as of then is newly created.
When no back-up file exists:
-
When 9S-121 (122) is performed, the equipment returns to the ready state of the 9S mode
without performing printing.
-
When 9S-221 (222) is performed, the equipment returns to the ready state of the 9S mode
and the error message "The file cannot be saved." appears on the panel.
When you want to create a back-up file if one does not exist:
A back-up file can be automatically created after the completion of the automatic gamma
adjustment when the easy set-up mode is restarted while a specified value such as 3 is set for
08-9022 (Production process management status for easy setup).
In this case, the current values are stored in the file, but not the ones for unpacking and
setting up.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
SELF-DIAGNOSIS MODES
BACKUP
CURRENT
128
160
Fig.5-33
5 - 38
S/N: xxxxxxxxx
TOTAL:
DF TOTAL:
TOSHIBA e-STUDIOxxxx
CODE
BACKUP
CURRENT
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved