Remove 2 screws on both ends of the doctor
sleeve and remove 2 coil springs.
Notes:
When the screws on both ends of the doctor
sleeve are removed, be sure to adjust the
doctor sleeve gap (0.45±0.05 mm) after
assembling.
(6)
Remove 1 screw and plate spring.
(only e-STUDIO356/456/506 / 357/457/507)
(7)
Remove 1 screw and take off the polarity
adjustment lever.
Notes:
Make a note of the position where the
polarity adjustment lever is pointing. (Mark
the position if needed.) When reassembling,
match the polarity adjustment lever with the
previously marked position on the scale.
(8)
Remove 2 screws and take off the bracket.
(9)
Remove 1 E-ring and take off the guide roller
on the front side.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Coil spring
Fig. 4-298
Polarity adjustment lever
Fig. 4-299
Fig. 4-300
E-ring
Fig. 4-301
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
4 - 105
Screw
Plate spring
Bracket
Guide roller
DISASSEMBLY AND REPLACEMENT