[Cb51] Staple Unit Sliding Motor (M7) Abnormality - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

MJ-1106/1108
Check item
Stapler
Stapler unit home position
sensor
Stapler unit shift motor
Parts to be replaced
Stapler unit home position
sensor
Finisher controller PC board

[CB51] Staple unit sliding motor (M7) abnormality

MJ-1032
Error
Staple unit sliding motor (M7)
Staple unit sliding home position
sensor (S3)
Probable cause
Staple unit sliding motor (M7)
abnormality
Staple unit sliding home position
sensor (S3) abnormality
Faulty cables and connectors
Finisher control PC board (FIN)
abnormality
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Measures
Move the stapler.
Fix any mechanical problem.
Check if there is a disconnection of the connector, incorrect
installation or breakage of the stapler unit home position sensor
(S10). If there is, reinstall the sensor correctly or replace it.
Check if the connector (CN21) on the finisher controller PC board is
disconnected from the stapler unit home position sensor (S10) and
the harnesses are open circuited. Correct if so.
Check if the connector (CN10) on the finisher controller PC board is
disconnected from the stapler unit shift motor (M9) and the
harnesses are open circuited. Correct if so.
Remark
The turning OFF of the staple unit sliding home position sensor (S3) is
not detected when the staple unit is moved from a point where this
sensor is turned ON to one point where this sensor is turned OFF after
the staple unit sliding motor (M7) has been driven at the specified
number of pulse.
The turning ON of the staple unit sliding home position sensor (S3) is
not detected when the staple unit is moved from a point where this
sensor is turned OFF to one point where this sensor is turned ON after
the staple unit sliding motor (M7) has been driven at the specified
number of pulse.
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the staple unit.
Measure the voltage on TP18 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
does not fall within the range mentioned, replace the sensor.
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connectors. (Finisher
control PC board (FIN): CN3, CN18)
If the error still occurs after replacing the staple unit, sensors and
connectors, exchange the finisher control PC board (FIN).
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 166
Timing of detection
Checking and measures
5% when shielded. If the voltage