Scanning System Related Service Call; [C260] Peak Detection Error (E-Studio206L/256/306/356/456/506) - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

8.3.11

Scanning system related service call

[C260] Peak detection error (e-STUDIO206L/256/306/356/456/506)

Classification
Scanning system related service
call
Proce
Check item
dure
1
Flat cable connecting the
SLG board and the CCD
board
2
Is the exposure lamp lit?
(Output check: 03-267)
3
Shading correction plate
Mirror
Exposure lamp
CCD board / Lens unit
SLG board
4
SLG board
Inverter board / LED board 1. Check if the harness of the exposure lamp is connected to
Exposure lamp
Supply harness
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Peak detection error
Result
1. Check if the harness at the SLG board side is
inserted into the slot of the connector properly.
2. Check if the lock of the connector at the SLG
board side is locked properly.
Yes
It is lit.
No
It is not lit.
1. Check if there is any scratch or stain on the shading
correction plate.
2. Check if the shading correction plate is any scratch or dirty.
1. Check if the mirror is tilted.
-
Check that the lens is reflected in the mirror looking at
carriage-1 from an upper position.
-
Check that the mirror is secured at the leaf spring.
1. Check if the exposure lamp is correctly lit.
2. Check if the harness is connected properly to the connector
of the inverter board or the LED board.
3. When the carriage is driven, check if the harness interferes
with it or parts are caught in it.
1. Check if the connector of the CCD board is connected
properly.
2. Check if the CCD board is installed properly. (Check that the
lens unit is not tilted or the screw is securely tighten.)
1. Check if the connector of the SLG board is connected
properly.
2. Check if the mounted parts on the SLG board are damaged
or abnormal.
3. Check if 10 V is output from the power supply for CCD.
1. Check if the supply cable is connected properly to the
connector.
2. Check if the mounted parts on the SLG board are damaged
or abnormal.
the inverter board or LED board properly.
2. Check if the supply harness to the inverter board is
connected properly.
3. Check if the mounted parts on the inverter board or the LED
board are damaged or abnormal.
1. Check if the harness of the exposure lamp is connected to
the inverter board or LED board properly.
2. Check if the exposure lamp is scratched or damaged.
1. Check if wiring of the supply harness (CN127) is abnormal.
2. Check if the harness is scratched or open circuited.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 128
Error content
Measure
Next Step
If normal,
go to 2.
3
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents