[C] When the update of engine ROM / Scanner ROM / RADF ROM failed
USB update failed
Failed twice or more?
YES
Clear [Update Error Flags].
Assist Mode :
Turn the power ON with [3] +
[CLEAR] + [ON/OFF]
Clear flags.
[1] - > [START]
Update download jig.
" 11.4.3 Engine ROM "
" 11.5.1 Scanner ROM "
" 11.5.2 RADF ROM " *
Update succeeded?
YES
Check ROM version.
" 11.7 Confirmation of
the updated data "
Is ROM version correct?
YES
Update completed
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
NO
Update USB.
*RADF: MR-3021/3022
NO
Failed twice or more?
YES
Replace target board.
NO
Update download jig.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
11 - 85
Check harness connection.
SYS board < -- > SYS board
NO