11.5.2

RADF firmware (MR-3021/3022)

Important:
Be sure to shut down the equipment before installing and removing the download jig.
Do not shut down the equipment during the update. The data could be damaged and not be
able to be operated properly.
Since the update data for the MR-3021 and the MR-3022 differ, be sure to install the correct.
[A] Update Procedure
(1)
Install the ROM to the download jig (K-PWA-DLM-320).
Make sure the direction is correct.
(2)
Press the [ON/OFF] button on the control panel to shut down the equipment and turn the power
OFF using the main power switch.
(3)
Take off the RADF rear cover.
(4)
Connect the download jig with the jig connector on the RADF control PC board.
(5)
Open the front cover.
(6)
Turn the power ON using the main power switch while simultaneously holding down the [0] and
[8] buttons.
Updating starts automatically and the LED on the download jig lights.