[C] Reproduction ratio of secondary scanning direction (Fine adjustment of main motor
rotation speed (Copier/Printer))
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON.  (Adjustment mode)
(1)
Press [1]  [FAX]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from the lower
(2)
drawer (Refer to *).
(3)
Check the grid pattern on the test chart printed out and measure the distance C from the 10th
line at the leading edge of the paper to the 30th line of the grid pattern.
* Normally, the 1st line of the grid pattern is not printed.
(4)
Check if the distance C is within 200±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance C again.
(Adjustment Mode)  (Key in code [4009])  [START]
 (Key in a value (acceptable values: 0 to 255))
 [OK] or [INTERRUPT] (Stored in memory)
 "100% A" is displayed
 Press [1]  [FAX]  (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance C becomes.
e-STUDIO206L/256/306/356/456/506: approx. 0.125 mm/step
e-STUDIO207L/257/307/357/457/507: approx. 0.25 mm/step
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
SETTING / ADJUSTMENT
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
6 - 10