4.14.6
Reverse motor (M14) (only installed for e-STUDIO356/456/506 /
357/457/507)
(1)
Take off the reverse unit.
( P. 4-124 "4.14.1 Reverse unit (only
installed for e-STUDIO356/456/506 / 357/
457/507)")
(2)
Release the harness from the harness
clamp.
(3)
Disconnect 1 connector and remove 3
screws, and take off the motor unit.
Notes:
When installing the reverse motor, make
sure to put on the timing belt.
(4)
Remove 2 screws and take off the reverse
motor.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Timing belt
Connector
Fig. 4-367
Fig. 4-368
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
4 - 129
Harness clamp
Motor unit
Reverse motor