[C130] Upper Drawer Tray Is Abnormal; [C140] Lower Drawer Tray Is Abnormal - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[C130] Upper drawer tray is abnormal

[C140] Lower drawer tray is abnormal

Classification
Paper feeding system related service
call
Proce
Check item
dure
1
Does the tray go up?
(Perform the output check
in the test mode: 03-242/
243)
2
Is the tray-up sensor
working?
(Perform the input check
in the test mode: 03-
[FAX]OFF/[6]/[B], /[7]/[B])
3
LGC board
Parts to be replaced
LGC board
Tray-up motor
Tray-up sensor
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Error content
Upper drawer tray is abnormal
Lower drawer tray is abnormal
Result
Yes
No
1. Check if the connector of the tray-up motor
is disconnected.
2. Check if the connector CN316 on the LGC
board is disconnected.
3. Check if the connector pins are
disconnected and the harnesses are open
circuited.
4. Check if the conductor pattern on the LGC
board is short circuited or open circuited.
5. Replace the LGC board.
Yes
No
1. Check if the connector of the sensor is
disconnected.
2. Check if the connector CN315 on the LGC
board is disconnected.
3. Check if the slit reaches the sensor.
4. Check if the connector pins are
disconnected and the harnesses are open
circuited.
5. Check if the conductor pattern on the LGC
board is short circuited or open circuited.
6. Replace the LGC board.
1. Check if the conductor pattern on the LGC
board is short circuited or open circuited.
2. Replace the LGC board.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
8 - 123
Measure
Remark
ERROR CODE AND TROUBLESHOOTING
Next
Step
2
3
8

Hide quick links:

Advertisement

Table of Contents
loading