[F700] Overwrite Error; [F800] Date Error - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[F700] Overwrite error

Classification
Other service call
Check item
Setting

[F800] Date error

Classification
Other service call
Check item
Setting
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Overwriting fails.
If a service call occurs again after the reboot, replace the
HDD.
The year 2038 problem
Reset the date, and request the administrator to set the date
and time.
1. Turn the power on while pressing the [6] and [CLEAR]
button.
2. Select [2] key, and then press the [START] button.
3. Press the [START] button on the confirmation screen
displayed. (The date is set to January 1st, 2011.)
4. Request the administrator to set the date and time.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 216
Error item
Measures
Error item
Measures

Hide quick links: