8.3.7

RADF jam

[E712] Jam not reaching the original registration sensor
Classification
RADF jam
Check item
Pickup roller
Feed roller
Separation roller
Original registration sensor
RADF board
Parts to be replaced
Original registration sensor
RADF board
Pickup roller
Feed roller
Separation roller
[E714] Feed signal reception jam
Classification
RADF jam
Check item
Empty sensor
Parts to be replaced
Empty sensor
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Error content

Jam not reaching the original registration sensor

Measures
Clean them if there are stained.
Sensor check (Perform the input check: 03-[FAX] ON[7]/[H])
Connector check (CN74)
Harness check
Board check
Connector check (CN74)
Harness check
Remark
Replace it if it is worn out
Replace it if it is worn out.
Replace it if it is worn out.
Error content

Feed signal reception jam

Measures
Sensor check (Perform the input check: 03-[FAX] ON[7]/[B])
Lever check
Connector check (CN75)
Harness check
Remark