[F106_6]/[F106_7]/[F106_8]/[F106_10] /[F106_UNDEF] ADI-HDD error: Error caused by reason
other than F106_0 to 5 errors
Classification
Other service call
Check item
Setting

[F109_0] Key consistency error (Consistency check operation error)

Classification
Other service call
Check Item
Setting
SRAM board
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
ADI-HDD error: Error caused by reason other than F106_0 to 5
errors
Perform [3]+[C]+[POWER]-> [3.Format HDD], and then
install the system software by performing
[4]+[9]+[POWER]-> [4.System Software(HD data)].
Notes:
The following items will be deleted by performing
[3]+[C]+[POWER]-> [3.Format HDD].
Message Log
Job Log
Spool Data (Print, Email reception)
Template
Key consistency error - Key consistency check on each key
data fails.
Reboot the equipment.
If it cannot be recovered, reinstall the software in the following
procedure.
(1)
Install the OS data.
 P. 11-15 "11.2.3 Update procedure"
(2)
Reinstall the master data and application program.
 P. 9-19 "9.3.3 Precautions and procedures when
replacing the HDD"
[E] Replace / Format HDD (Step (3) and later in [E]
Replace / Format HDD)
(1)
If the error is not cleared even after reinstallation, replace
the SRAM board.
 P. 9-31 "9.3.8 Precautions and Procedures when
replacing SRAM board"
(2)
If the error is not cleared even after replacing the SRAM
board, replace the SYS board.
 P. 9-24 "9.3.4 Precautions and Procedures when
replacing the SYS board"