Toshiba e-STUDIO206L Service Manual page 447

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

(9)
Attach the developer material cover and
tighten 2 screws.
Notes:
1. After the developer material has been
replaced, adjust the auto-toner sensor.
(See  P. 6-2 "6.2 Adjustment of Auto-
Toner Sensor".)
2. When installing the developer unit upper
cover, make sure that the side seal
comes between the developer unit upper
cover and rubber seal on the cover.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Fig.6-60
Rubber seal
Developer unit
upper cover
Fig.6-61
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
6 - 67
Developer
material cover
Side seal