Notes:
1. The CCD lens unit is adjusted finely, so
the readjustment or replacement of some
parts is impossible in the field. The lens
unit must be replaced on a unit basis.
2. Handle the lens unit with care. Do not
hold the adjustment unit or lens.
3. Count the number of lines [3] and write it
down for later reference before removing
the CCD lens unit. When installing the
CCD lens unit, the same number of lines
needs to be visible.
4. When replacing the lens unit, do not
touch the screws (7 places).
4.6.6
Carriage home position sensor
(1)
Take off the original glass.
P. 4-45 "4.6.1 Original glass"
(2)
Remove the seal [1]. Disconnect the 1
connector and release 3 latches, and then
remove the carriage home position sensor
[2].
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
DISASSEMBLY AND REPLACEMENT
Fig. 4-138
Fig. 4-139
Fig. 4-140
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved