[B] Adjustment of the magnification ratio of the lens
Notes:
Perform this adjustment only when the lens unit is taken off or replaced.
Make sure that the primary scanning reproduction ratio (printer section) is correct before this
adjustment.
(1)
Place a ruler on the original glass (in the primary scanning direction) and make a copy on A4/LT-
sized paper at 100% reproduction ratio.
(2)
Compare the copied ruler with the actual
ruler.
(3)
If each mark on the rulers differs, perform the adjustment with the following procedures.