Heater Control Circuit - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

3.15.4

Heater Control Circuit

[ 1 ] Configuration
In this equipment, the surface temperature of the fuser roller is controlled by turning ON/OFF 3 heater
lamps (center, side and sub) which have different heat-generating positions with the command from the
engine-CPU on the LGC board.
The surface temperature of the fuser roller is detected by 3 thermistors (center, side and edge) and
then the information of the temperature is transmitted to the engine-CPU and each control circuit.
Based on the detected temperature, the engine-CPU transmits the control signal of the heater lamp to
the control circuit (TRC: Triac) of each heater lamp on the switching regulator via the temperature
control circuit. The power supply to the fuser roller is thus controlled by driving TRC. The temperature
control circuit detects the overheating of the fuser roller. In case that the surface temperature of the
fuser roller has exceeded the specified temperature, the temperature control circuit turns the heater
lamp OFF. If the temperature control circuit does not function for some reason and the fuser roller is
abnormally overheated as the result, a relay OFF circuit transmits a relay OFF signal to turn off the
relay, and to turn the power OFF forcibly.
If the temperature control circuit does not function for some reason and the fuser roller is abnormally
overheated as the result, a forcible power-OFF circuit transmits a reset signal to the power switch to
turn the power OFF forcibly. In addition, if these control circuits do not function with thermistor
abnormality or other reasons and the fuser roller is abnormally overheated as the result, 2 thermostats
(front and center ones in the fuser unit) shut off the power supply to the heater lamps to protect the
equipment.
For e-STUDIO206L/256/306 / 207L/257/307, the sub heater lamp is not installed.
Fuser unit
Fuser front
Fuser center
thermostat
thermostat
Front
Fuser roller
Center heater lamp
Sub heater lamp
Side heater lamp
Center
Side
thermistor
thermistor
A/D
converter
CPU
Relay OFF circuit
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Switching regulator
Rear
Center heater lamp
control circuit (TRC1)
Sub heater lamp
control circuit (TRC3)
Side heater lamp
control circuit (TRC2)
Edge
thermistor
ASIC
Temperature control circuit
Relay OFF signal
Fig. 3-54
3 - 75
L
Noise
N
filter
Main power switch
Relay
AC line
DC line
are only installed for e-STUDIO356/456/506 / 357/457/507.
LGC board
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
OUTLINE OF THE MACHINE
3

Hide quick links:

Advertisement

Table of Contents
loading