Toshiba e-STUDIO206L Service Manual page 1031

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

(6)
Connect the download jig with the jig connector (CN602) on the FAX board.
(7)
Turn the power ON using the main power switch while simultaneously holding down the [0] and
[8] buttons.
Updating starts automatically and the LED on the download jig lights.
(8)
After the update is completed properly, the LED on the download jig blinks.
The LED starts blinking approx. 30 sec. after the update starts. It is assumed that the update has
failed if it does not start blinking even though 1 min. has passed. In this case, shut down the
equipment and check the following items. Then clear the problems and restart updating from the
beginning.
Is the download jig connected properly?
Is the ROM installed to the download jig properly?
Is the updating data written on the ROM of the download jig properly?
Do the download jig and the equipment operate properly?
(9)
Press the [ON/OFF] button on the control panel and turn the power OFF using the main power
switch and remove the download jig. Install the cover plate.
(10) In the FAX Clearing Mode, perform the "FAX Set Up".
Confirm the destination setting is correct in the Setting Mode (08).
08-9000: Destination setting of the equipment
08-9001: Destination setting of the FAX machine
Turn the power ON using the main power switch while [1] button and [*] button are pressed
simultaneously.
Key in "100".
Press the [START] button.
Notes:
If the equipment does not work properly after the operation (8), follow the procedure below and
then perform the "Clearing the image data" in the FAX Clearing Mode to erase the image data in
the memory.
Confirm the destination setting is correct in the Setting Mode (08).
08-9000: Destination setting of the equipment
08-9001: Destination setting of the FAX machine
Turn the power ON using the main power switch while [1] button and [*] button are pressed
simultaneously.
Key in "102".
Press the [START] button.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Fig.11-75
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
11 - 75
FIRMWARE UPDATING
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents