<<Output connector>>

Not linked with the door switch

Connector
CN418
For the SYS board
CN415
For the LGC board, FUS board, PFP/LCF (via LGC
board), Bridge unit / Job separator / Offset tray (via
LGC board), finisher
CN419
For the SLG board, RADF

Linked with the door switch

Connector
CN415
For the LGC board, High-voltage transformer (via
LGC board), PFP/LCF (via LGC board), Bridge unit /
Job separator / Offset tray (via LGC board), finisher
CN417
For the Main motor, MOT/MOT2 board
CN419
For the SLG board, RADF
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Destination
Destination
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
3 - 87
Voltage
+5VS, +5VA, +5VB, +12VA
+5VB
+5VB, +12VB
Voltage
+5VD, +24VD1, +24VD4
+24VD2
+24VD1, +24VD3