(9)
Copy the data in the EEPROM to SRAM (08-4582).
(10) Turn the power OFF.
(11) Update the engine ROM using the USB Media.
 P. 11-11 "11.2 Firmware Updating with USB Media"
(12) Turn the power OFF.

(13) Start up with the Setting Mode (08).

(14) Check the version of the engine ROM (08-9901).
(15) Turn the power OFF.
Notes:
If the equipment does not work properly after the LGC board was replaced, perform printer all
clear in accordance with the procedure explained in the contents of 08-9090 in chapter 15.
9.3.6

Procedure when replacing the battery on LGC board

(1)
Start up with the Setting Mode (08).
(2)
Copy the data in the SRAM to EEPROM (08-4581).
If you cannot start up with the setting mode (08), begin from step (3).
(3)
Turn the power OFF.
(4)
Remove a battery from the LGC board.
(5)
Attach a battery to the LGC board.
(6)
Start up with the Setting Mode (08).
(7)
Copy the data in the EEPROM to SRAM (08-4582).
(8)
Turn the power OFF.
9.3.7
Procedures when replacing the SLG board (e-STUDIO206L/256/
306/356/456/506)
Notes:
Before replacing the SLG board, perform the following procedure.
 P. 9-16 "9.3.1 Precautions when replacing PC boards"
Be sure to follow the procedure below when the SLG board is replaced.
(1)
Confirm that the power is turned OFF.
(2)
Replace the SLG board.
 P. 4-44 "4.5.13 SLG board (SLG)"
(3)
Update the scanner ROM using the USB media.
(4)
Turn ON the main power switch and perform "Data transfer of characteristic value of scanner /
SYS board -> SLG board (05-3209)".
(5)
Turn the power OFF.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
9 - 29
REPLACEMENT OF HDD/PC BOARDS