4.11.9

Drum cleaning blade

(1)
Take off the drum
( P. 4-93 "4.11.8 Drum").
(2)
Remove 2 screws and take off the drum
cleaning blade.
Notes:
Be careful not to touch or scratch the edge of
the drum cleaning blade.

4.11.10 Drum separation finger

(1)
Take off the drum
( P. 4-93 "4.11.8 Drum").
(2)
Remove 1 screw of each unit to take off the
drum separation finger units (2 pc.).
Notes:
1. When replacing the drum separation
fingers, make sure that the drum has
been taken off first since the fingers may
scratch the drum surface.
(3)
Remove the spring and take off the drum
separation fingers.
Notes:
When the drum separation fingers have been
replaced, check if the pressure movement is
normal by moving them with your hands.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
DISASSEMBLY AND REPLACEMENT
Drum cleaning blade
Fig. 4-266
Drum separation finger unit
Fig. 4-267
Drum separation finger
Fig. 4-268
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved