E-Studio206L/256/306/356/456/506; E-Studio207L/257/307/357/457/507; Scanner - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

7.7.1

Scanner

e-STUDIO206L/256/306/356/456/506

b
a
d
e

e-STUDIO207L/257/307/357/457/507

b
d
e
Items to check
a
Original glass
b
ADF original glass
c
Mirror 1
d
Mirror 2
e
Mirror 3
f
Reflector
g
Lens
h
Exposure lamp
i
Automatic original
detection sensor
j
Slide sheet
(front and rear)
* a, b. Original glass/ADF original glass
Clean both sides of the original glass and ADF original glass.
Notes:
Make sure that there is no fingerprints or oil staining on part of the original glass on where the
original scale is mounted since the shading correction plate is located below the scale to be
scanned.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
f
c
h
Fig. 7-7
f
h
a
j
c
Fig. 7-8
Cleaning
Lubrication
A or B
B
B
B
B
B
B
B
B
7 - 17
g
j
i
g
Replacement
Operation
(x 1,000 sheets)
check
R3
R3
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
PREVENTIVE MAINTENANCE (PM)
Parts list
<P-I>
22-3
22-1
23-5
12-13
23-3
12-16
15-1
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents