[Cb30] Movable Tray Shift Motor Abnormality - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

Check item
Assist arm motor (M10)
Finisher control board
Replace parts
Assist arm motor
Finisher control board

[CB30] Movable tray shift motor abnormality

MJ-1101/1107
Classification
Finisher related service call
Check Item
Movable tray
Movable tray shift motor (M7)
Movable tray position A, B, and C
sensors (S13, S14, and S15)
Replacement part
Movable tray shift motor (M7)
Movable tray position A, B, and C
sensors (S13, S14, and S15)
Finisher controller PC board
MJ-1106/1108
Check item
Movable tray
Movable tray shift motor (M12)
Movable tray position A, B, and C
sensors (S13, S14, and S15)
Parts to be replaced
Movable tray shift motor (M7)
Movable tray position A, B, and C
sensors (S13, S14, and S15)
Finisher controller PC board
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Motor check
Connector check
Harness check
Connector check (CN13)
Board check
Movable tray shift motor abnormality: The movable tray shift
motor is not rotating or the movable tray is not moving normally.
If there is mechanical problem when the movable tray is moved,
fix the mechanism.
Check the connectors and harnesses between the movable tray
shift motor (M7) and the finisher control PC board (CN8).
Connector check
Sensor check
Measures
If there is mechanical problem when the movable tray is moved,
fix the mechanism.
Check the connectors and harnesses between the movable tray
shift motor (M12) and the finisher control PC board (CN16).
Connector check
Sensor check
Remark
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 158
Measures
Remarks