6.2
Adjustment of Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
<Procedure> (Adjustment Mode (05-2000))
(1)
Install the process unit into the equipment.
(2)
While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
(3)
Key in code [2000] and press the [START] button.
The display changes as follows.
[2000]
Notes:
•
A indicates the controlled value of the auto-toner sensor output. Press the Up or Down button
to change the value.
•
B indicates the output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
•
C indicates the latest adjustment value.
(4)
After about two minutes, the value B automatically starts changing.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
SETTING / ADJUSTMENT
100%
[0][5]
TEST MODE
[POWER]
Fig.6-2
B
230%
[START]
TEST MODE
128
C
Fig.6-3
230%
TEST MODE
128
Fig.6-4
A3
A
2000
A3
2000
WAIT
128
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
6 - 2
A3
128
A