6.6.2

Density adjustment

Adjusts the center density and the variation of density adjustment buttons.
e-STUDIO206L/256/306/356/456/506
Color
Original mode
Text
Text
Photo
/Photo
8339
8340
8341
-
8344
8345
-
8348
8349
e-STUDIO207L/257/307/357/457/507
Color
Original mode
Text
Text
Photo
/Photo
8339
8340
8341
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
Black
Original mode
Text/
Text
Photo
Photo
7444
7445
7446
7456
7457
7458
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
SETTING / ADJUSTMENT
Item to be adjusted
User
custom
8380
Manual density center
value
8381
Manual density light step
value
8382
Manual density dark step
value
Item to be adjusted
User
custom
8380
Manual density center
value
Gray
Item to be
Scale
adjusted
User
custom
7475
7447
Manual density
center value
7478
7459
Automatic density
6 - 34
<Adjustment Mode (05)>
Remarks
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255
(Default: 128)
Sets the changing amount by 1 step at the
density adjustment on the control panel.
The larger the value is, the lighter the light
side becomes.
Acceptable values: 0 to 255
(Default: 20)
Sets the changing amount by 1 step at the
density adjustment on the control panel.
The larger the value is, the darker the dark
side becomes.
Acceptable values: 0 to 255
(Default: 20)
<Adjustment Mode (05)>
Remarks
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255
(Default: 128)
<Adjustment Mode (05)>
Remarks
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255
(Default: 128)