3.Touch the center of "+" mark displayed on the lower left of the LCD.
4.Touch the center of "+" mark displayed on the lower right of the LCD.
(4)
Perform the initialization at the software version upgrade (08-9030).
(5)
Initialize the NIC information (08-9083).
(6)
Enter the serial number (08-9601).
Key in the serial number on the label attached to the rear cover, and then press the [OK] button.
(7)
Turn the power OFF.
[K] Reinstall license
If the license was returned in "[B]Return License", reinstall it with the following procedure.
(1)
Turn the power ON while pressing [0] and [8] simultaneously.
(2)
Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [OK] button without entering anything.)
(3)
Key in [3840], and then press the [START] button.
(4)
Press the [INSTALL] button.
(5)
Install the one-time dongle in the equipment (the one which you used for returning the selected
license before replacing the equipment). Then press the [OK] button.
(6)
Select the license to be installed, and then press the [INSTALL] button.
(7)
The screen for notifying that the installation will be started is displayed. Then press the [YES]
button.
(8)
After 10 to 40 seconds have passed, the screen for notifying the success of the performance is
displayed. Then press the [OK] button. If the screen for notifying a failure of the performance is
displayed, quit this operation by pressing the [NO] button. Then check that the one-time dongle is
installed properly in the equipment.
(9)
Check that the installed license is displayed on the license list.
Remarks:
If there are any other licenses to be installed, repeat from step (4). If there are no other licenses
to be installed, press the [CLOSE] button, and then turn the power OFF.
[L] Enable HDD encryption
If the HDD encryption function is used, follow the procedure below.
(1)
Start up with the Setting mode (08).
(2)
Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [OK] button without entering anything.)
(3)
Enable the HDD encryption function. (Set "3" for 08-8911. Or set "1" for 08-8911 and "1" or "2" for
08-9379.)
(4)
Turn the power OFF.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
9 - 35
REPLACEMENT OF HDD/PC BOARDS
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents