[E430] ADU opened during printing
Classification
Cover open jam
Proce
Check item
dure
1
Is the ADU open?
2
Is the ADU opening/
closing switch working?
(Perform the input check
in the test mode: 03-
[FAX]ON/[9]/[F])
3
Replacing board
Parts to be replaced
ADU opening/closing switch
LGC board
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
ADU open jam
Result
Yes
Remove the paper if there is any, then close
the ADU.
No
Yes
No
Check if the connector of the ADU opening/
closing switch is disconnected.
Check if the connector CN311 on the LGC
board is disconnected.
Check if the connector pins are
disconnected and the harnesses are open
circuited.
Check if the conductor patterns on the LGC
board are short circuited or open circuited.
Replace the ADU opening/closing switch.
Replace the LGC board.
Replace the LGC board.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507