Check item
3. Clear the status counter
Parts to be replaced
LGC board
Thermistors

[C4B0] Fusing error counter for out-of-specifications

Classification
Fuser unit related service call
Check item
1. Check the LGC board
2. Clear the status counter
Parts to be replaced
LGC board

[C4C0] Fuser unit new/old detection fuse abnormality

Classification
Fuser unit related service call
Check item
1. Check the fuser unit.
2. Check the PC board
Parts to be replaced
Fuser unit.
PC board
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
1. Change the value of the status counter (08-2002) to "0".
("62" is written in 08-2002.)
Error content
Fusing error counter for out-of-specifications
1. Check if the conductor pattern on the LGC board is open or
short circuited.
2. Check if the memory (IC41) is installed properly.
3. Replace the LGC board.
1. Change the value of the status counter (08-2002) to "0".
Error content
Fuser unit new/old detection fuse abnormality
1. Are the connectors disconnected?
2. Are the harnesses open circuited?
3. Replace the fuser unit.
1. Are the connectors disconnected?
2. Are the harnesses short circuited or open circuited?
3. Replace the board.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507