Check item
3
SLG board
4
Scan motor
Parts to be replaced
Carriage home position sensor
Carriage home position sensor
harness
SLG board
Scan motor
Scan motor harness
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
1. Check if the harness of the carriage home position sensor on
the SLG board is connected properly.
2. Check if the mounted parts on the SLG board are damaged
or abnormal.
3. Check if 24 V on the SLG board is short-circuited.
4. Check if 24 V is supplied to the SLG board.
1. Check if the belt tension is loosened.
2. Check if the motor fixing screw is loosened.
3. Check if the carriage wire and the timing belt come off.
4. Check if the connector is connected to the motor properly.
5. Check if the harness of the motor is caught or open circuited.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 132
Measure