Toshiba e-STUDIO206L Service Manual page 533

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

* a. Fuser roller
When replacing the fuser roller, apply small amount of grease on the inside of fuser roller
bearings.
Do not deform or damage the fuser roller during the cleaning.
(*1) The model for the cleaning is e-STUDIO207L/257/307/357/457/507.
* b.
roller
Pressure
Do not deform or damage the pressure roller during the replacing.
Do not deform or damage the pressure roller during the cleaning.
(*1) The model for the cleaning is e-STUDIO207L/257/307/357/457/507.
* c. Separation fingers for fuser roller
The paper jam may be caused if the tip of the finger is damaged or deformed. If there is any
problem with it, replace the finger with a new one regardless of the number of output pages
which have been made. Do not damage the tip of the finger during the cleaning. The finger may
be damaged if the toner adhering to the tip of it is scraped off forcibly. Replace the finger if the
toner is sticking to it heavily.
* e. Thermistor
Clean the thermistor with alcohol if the toner or dirt is sticking to it when the fuser roller is
replaced.
Do not deform or damage the thermistor during the cleaning. Replace the thermistor with a new
one if it is damaged or deformed regardless of degree.
* h. Exit sensor actuator
If toner has adhered, wipe it off with alcohol.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
7 - 27
PREVENTIVE MAINTENANCE (PM)
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents