(3)
List of messages
ID
Level
1800
Info
Meaning: The temperature at the part shown in %s2 of the module shown in %s1 is beyond
the normal value but does not reach the warning level.
Action: Nothing required. If this message frequently appears, check if something prevents the
unit from cooling down
1801
WARNING
Meaning: The temperature at the part shown in %s2 of the module shown in %s1 is beyond
the warning level.
Action: Although the device can keep running, the high temperature can cause a fault. Thus,
check if something prevents it from cooling down, such as failure in air conditioners or in fan
modules of the unit, and inlet ports covered with dust.
1802
FAIL
Meaning: The temperature at the part shown in %s2 of the module shown in %s1 is
exceedingly high.
Action: The module with a high temperature may stop working to protect hardware. Consult
your reseller or maintenance personnel.
Check if something prevents it from cooling down, such as failure in air conditioners or in fan
modules of the unit, and inlet ports covered with dust.
1803
WARNING
Meaning: The temperature at the part shown in %s2 of the module shown in %s1 is below the
warning level.
Action: Although the device can keep working, check if the temperature is proper where the
device is installed.
1805
Info
Meaning: The temperature at the part shown in %s2 of the module shown in %s1 is back to
the normal level.
Action: This shows just information. Nothing required.
1810
WARNING
Meaning: The voltage at the part shown in %s2 of the module shown in %s1 is beyond the
warning level.
Action: Although the device can keep working, the high voltage can cause a fault. Consult
your reseller or maintenance personnel.
1811
FAIL
Meaning: The voltage at the part shown in %s2 of the module shown in %s1 is exceedingly
high.
Action: The module with high voltage may stop working to protect hardware. Consult your
reseller or maintenance personnel.
1813
WARNING
Meaning: The voltage at the part shown in %s2 of the module shown in %s1 is below the
warning level.
Action: Although the device can keep working, the low voltage can cause a fault. Consult
your reseller or maintenance personnel.
1814
FAIL
Description
On module <%s1>, the temperature <%s2> exceeded the normal
level.
On module <%s1>, the temperature <%s2> exceeded the warning
level.
On module <%s1>, the temperature <%s2> rose too far above
tolerable levels.
On module <%s1>, the temperature <%s2> fell below the warning
level.
On module <%s1>, the temperature <%s2> has been restored to a
tolerable level.
On module <%s1>, the voltage <%s2> exceeded the warning level.
On module <%s1>, the voltage <%s2> rose too far above tolerable
levels.
On module <%s1>, the voltage <%s2> fell below the warning level.
On module <%s1>, the voltage <%s2> fell too far below tolerable
990