ID
Level
Meaning: An event related to an energy-saving feature was recorded for the partition
indicated by %s1.
ID indicates the event type.
0x3f: A power consumption value was set.
0x41: The maximum power consumption was changed.
0x42: The minimum power consumption was changed.
0x80: The power consumption limit was changed.
Action: No particular action is required.
142D
WARNING
On partition <%s1>, an attention event related to power-saving of the
server blade was logged. ID=(0x%s2)
Meaning: A significant event related to an energy-saving feature was recorded for the
partition indicated by %s1.
ID indicates the event type.
0x11: Power consumption remained above the power consumption limit for a pre-defined
period.
0x12: The partition is operating at the minimum power consumption because the power
consumption limit is set below the minimum power consumption value.
Action: Review the power control settings as required.
1470
FAIL
Partition <%s1>, Watchdog timer has expired.
Meaning: A watchdog timer timed out on the partition indicated by %s1.
The partition will restart. If the N+M cold standby function is enabled for the partition,
processing will fail over to the standby server.
Action: Contact your reseller or maintenance personnel.
1620
Info
On physical partition <%s1>, startup of LP was halted because non-
LP compatible server blades exist in the configuration.
Meaning: LPAR manager cannot start because a server blade in the physical partition
indicated by %s1 lacks a valid LPAR manager license.
Action: Check the LPAR manager license type and whether the license is present and valid.
If LPAR manager does not start and this message is output despite the server blade having a
valid license, contact your reseller or maintenance personnel.
1621
Info
On physical partition <%s>, a LP dump was logged.
Meaning: LPAR manager dump was collected from the partition indicated by %s.
Action: No action is required.
1622
FAIL
On physical partition <%s1>, an error that is fatal to the system
occurred in LP.
Meaning: A critical error on the physical partition indicated by %s1 caused the system to shut
down.
Action: Contact your reseller or maintenance personnel.
1623
FAIL
On physical partition <%s1>, an error occurred in LP.
Meaning: An LPAR manager error occurred on the physical partition indicated by %s1.
Action: Contact your reseller or maintenance personnel.
1624
FAIL
On physical partition <%s1>, an error occurred in LP assist.
Meaning: An error LPAR manager assist error occurred on the physical partition indicated
by %s1.
Action: Contact your reseller or maintenance personnel.
1625
FAIL
On physical partition <%s1>, an error occurred in an LPAR.
Meaning: An LPAR error occurred on the physical partition indicated by %s1.
Action: Contact your reseller or maintenance personnel.
1626
FAIL
On physical partition <%s1>, an error that is fatal to the system
occurred due to an H/W failure.
Message
Description
776