Operation with F10: Update System Config should be
done with no activated LPAR. If it is operated with an
activated LPAR, network communication between
LPARs is lost for several minutes. SC/BSM displays
Deactivate as the LPAR manager state and no error
notification is performed.
The operation with F10: Update system Config provides
a temporary change in the screen when LPAR manager
is running. Thus, the setting, which is not saved, will
disappear when LPAR manager is rebooted. Execute
F9: Save configuration in the LPAR manager Menu
screen to save the new setting.
If you change a BSM IP address, BSM alert port, or alert
language in this screen, the setting values are effective
only during LPAR manager running and not saved with
F9: Save Configuration. When you reboot LPAR
manager, the value set in the management module will
become the initial value.
Operation with F10: Update System Config is not required to
reflect a setting change. It might take about 10 seconds to
reflect a setting change.