Description: Firmware update has completed on the module shown in Location X.
Action: None.
FDD0
Warning
Warning about the system configuration is detected.
Description: The system configuration has problems.
Action: When you have changed the system configuration before the message appears,
check if there is anything wrong with the change. If there was no change in the configuration
or nothing wrong with the changed configuration, contact your reseller or maintenance
personnel.
FDD1
Error
System configuration error is detected.
Description: The system configuration has problems.
Action: When you have changed the system configuration before the message appears,
check if there is something wrong with the change. If there was no change in the
configuration or nothing wrong with the changed configuration, contact your reseller or
maintenance personnel.
System power activation is deterred for system configuration error.
FDD2
Warning
(Location:X)
Description: Improper system configuration has deterred the system from powering on.
Location X is unavailable for activation.
Possible causes:
Problems with configuration and settings, including incorrect hardware configuration and lack
of power .
When maintenance is being performed, the server blade is targeted for maintenance or
power to the server blade with error is controlled.
Action: Find and solve the problem to stop power on. If the problem is unknown, contact your
reseller or maintenance personnel.
FDD3
Error
Power supply capacity is insufficient.
Description: Power supply capacity is not enough.
Action: Check if power supply modules are properly installed. If they are, contact your
reseller or maintenance personnel.
FDD5
Error
The total number of cooling fan modules is insufficient.
Description: The total number of cooling fan modules is not enough.
Action: Check if cooling fan modules are properly installed. If they are, contact your reseller
or maintenance personnel.
FF05
Information
LAN port <X> has switched to another port.
Description: A LAN port shown as X, for which redundancy is enabled, has switched to
another port.
Action: When this message alone is displayed, there is no problem due to redundancy
enabled. If FD78 is displayed together with this FF05, check connection of the specified LAN
port. If the message is shown when the LAN cable is correctly attached and is not broken,
follow the action shown in ID: FD78.
FF06
Information
LAN port <X> has recovered from an error.
Description: The LAN port shown as X, which switched to another port in message ID: FF05,
has switched back.
Action: None.
FF08
Warning
The synchronization of time is not performed. (Location:X)
Description: Time synchronization by NTP server is not performed in Location X.
Action: Check if communication is available between the management module and NTP
server. Also check the NTP server settings in the management module, and NTP server
connection and settings. Check the time clock in the specified module, and correct the time if
necessary.