Hitachi Compute Blade 2000 User Manual page 963

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

If you type E in the DL command menu and press Enter, system event logs are
displayed.
-- System event log --
Timestamp
Message
------------------- ------ ------- -----------------------------
2009-12-25 04:10:12 PS0
Supply module#z: installed
2009-12-25 04:10:12 PS1
Supply module#z: installed
2009-12-25 04:10:12 PS0
Supply module#z: Power On
2009-12-25 04:10:12 PS1
Supply module#z: Power On
2009-12-25 04:10:16 IO0
module#z: Control signal cable installed
2009-12-25 04:10:16 IO0
module#z: Control signal cable installed
Hit enter key.
Items of the system event log are described in the table below.
Description of
Item
item
When a log is
Timestamp
created. (local
time)
Where the
Module
event occurs
Level
System
Event data
event log
Message
Event message
Module
Level
Info
001D 02 6100 04 0850 6FA00000 Power
Info
001E 02 6100 04 0850 6FA00001 Power
Info
001F 02 6100 04 F2F8 07A82000 Power
Info
0020 02 6100 04 F2F9 07A82001 Power
Info
0021 02 6100 04 F2F8 07A80A60 I/O
Info
0022 02 6100 04 F2F8 07A80A61 I/O
Value
YYYY-MM-DD
YYYY: AD year; MM: month; DD: day; hh:
hh:mm:ss
hour; mm: minute; ss: second
IOX
I/O module
IOAX
I/O adapter
PSX
Power supply module
FANX
Fan module
ETC
Others including "Unknown"
Info
Information
Caution
-
WARNING
-
FAIL
-
IIII RR gggg ee
IIII: Record ID
ssSS
RR: Record type
ee11223344
gggg: Generator ID
ee: evn revision
ss: Sensor type
SS: Sensor number
ee: Event trigger
11: Event data 1
22: Event data 2
33: Event data 3
Character string
Displayed in ASCII.
912
System
event
log
Description of value

Advertisement

Table of Contents
loading

Table of Contents