Hitachi Compute Blade 2000 User Manual page 826

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

(3)
List of messages
ID
Level
1483
FAIL
Meaning: A test of the N+M cold standby function (immediate failover) was performed on the
partition indicated by %s1.
Action: No particular action is required as the message relates to a test.
1484
FAIL
Meaning: A test of the N+M cold standby function (other than immediate failover) was
performed on the partition indicated by %s1.
Action: No particular action is required as the message relates to a test.
14E3
Info
Meaning: Device information was updated. Upon receiving this alert, BSM will update its
internal management information by acquiring the latest information from the management
module.
Action: No particular action is required.
14E4
Info
Meaning: Module information was updated. Upon receiving this alert, BSM will update its
internal management information by acquiring the latest information from the management
module.
Action: No particular action is required.
14E5
Info
Meaning: Upon receiving this alert, BSM will update its internal management information by
acquiring the latest information from the management module.
No particular action is required.
14EA
Info
Meaning: Upon receiving this alert, BSM will update its internal management information by
acquiring the latest information from the management module.
Action: No particular action is required.
14EB
Info
Meaning: A Smart Configure process was begun on the partition indicated by %s1. %s2
indicates the type of smart configuration being performed.
acquisition: Smart Configure for acquiring information from a server blade
setting: Smart Configure for setting information on a server blade
diagnosis: Smart Configure for testing a server blade
Action: No particular action is required.
14EC
Info
Meaning: A Smart Configure process ended on the partition indicated by %s1. %s2 indicates
the type of smart configuration that was performed (see 14EB).
Action: No particular action is required.
142C
Info
Description
Partition <%s1>, Error alert (immediate replacement) is sent by the
user request operation.
Partition <%s1>, Error alert (delayed replacement) is sent by the
user request operation.
System information update alert is sent.
Module information update alert is sent.
Module information update alert is sent (error/degradation).
The BMC IP address of the server blade indicated by %s was
updated.
Partition <%s1>, pre-boot configuration started (Data %s2
procedure).
Partition <%s1>, pre-boot configuration completed (Data %s2
procedure).
On partition <%s1>, a power-saving event of the server blade was
logged. ID=(0x%s2)
775
Message

Advertisement

Table of Contents
loading

Table of Contents