If you enter S in the BSM command menu and press Enter, the current setting is
displayed in numerical order shown in the table below. To proceed to the next setting,
press Enter, or enter a setting value and press Enter.
Menu
1
2
3
4
5
6
If you enter a duration period for connection retries, the changed setting is displayed. A
confirmation message appears. At the prompt, enter Y and press Enter, and the
SC/BSM connection setting is saved. To cancel the setting, enter N and press Enter,
or just press Enter.
(S,[Q]) : S (Enter)
Name : BSM_1
([Unchange]) : BSM_01 (Enter)
IP address : 192.168. 0.253
([Unchange]) : 192.168.0.254 (Enter)
Alert port : 20079
(1-65535,[Unchange]) : 20078 (Enter)
Alert level : Alert
(0=All,1=Alert,2=Information,3=Disable,[Unchange]) : 0 (Enter)
Retry interval (sec) : 5
(5-50,[Unchange]) : 6 (Enter)
Retry duration (min) : 10
(4-20,[Unchange]) : 5 (Enter)
-- Manager detail setting --
No. : 1
Name : BSM_01
IP address : 192.168. 0.254
Alert port : 20078
Alert level : All
Retry interval (sec) : 6
Retry duration (min) : 5
Confirm? (Y,[N]) : Y (Enter)
- Writing setting was completed.
Hit enter key. (Enter)
Do not perform an N+M cold standby switching test by
issuing an alert in this screen together with LPAR migration
targeted to that partition. See Chapter 12: Logical partitioning
manager for further information.
Description
SC/BSM name
SC/BSM IP address
SC/BSM alert report number
Alert level to notify SC/BSM
Intervals between connection retries: 5 to 50 seconds
Interval duration: 4 to 20 minutes
573