HCSM server settings
#
Item
1
IP address
2
Status
3
Alert port number
4
Alert level
5
Alert retry interval
(min)
6
Alert retry duration
(min)
7
Add
8
Edit
9
Delete
Sending an alert notification
#
Item
1
Partition
2
Alert type
3
Operation
Disconnect
#
Item
1
HCSM
2
Operation
 Role-dependent variation in available operations
To display and configure information in the HCSM setup view, the user must have
chassis permission.
Description
Shows HCSM IP addresses registered in the
management module.
Shows whether or not this HCSM is connected to the
management module.
Shows the destination HCSM port number. Default value:
22611
Shows an alert level to notify one of the following values.
Only failure: Notifies only failure-level alerts, no warning-
and information level alerts.
Warning and failure: Notifies failure- and warning-level
alerts, no information-level alert.
Do not notify: Notifies no alerts.
Shows the alert retry interval from 1 to 4 minutes.
Shows the alert retry duration from 4 to 15 minutes in
case that an alert cannot be notified to HCSM due to
temporary failure in the network.
Adds HCSM to connect.
Edits settings for connection to the selected HCSM
Deletes connection of the selected HCSM.
Description
Selects a partition to issue a test alert.
Selects a test alert type from the following two.
- N+M cold standby (instant failover)
- N+M cold standby (delayed failover)
Sends a test alert.
Description
Selects HCSM to disconnect
Disconnects the selected HCSM.