Hitachi Compute Blade 2000 User Manual page 1512

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

Message content
LPAR manager detected error of network communication
Level
Error
Explanation
A communication fault occurred between LPAR manager and the
switch and management module.
What to do
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message content
LPAR manager detected failed SR-IOV device was assigned to
Level
Warning
Explanation
Detected that the LPAR, to which the isolated PCI device is
assigned, is activated.
What to do
The PCI device is not available on the LPAR due to the error. If the
PCI device is not automatically recovered, execute Force Recovery
to release the isolation. Then, reboot the guest OS to use the PCI
device.
Message content
LPAR manager detected failed SR-IOV feature was recovered.
Level
Information
Explanation
Detected the isolated PCI device is recovered.
What to do
None. The PCI device has been recovered from the error state. The
PCI device isolated on the LPAR will run properly after the guest OS
reboot.
Message content
LPAR manager detected Hardware error for Shared FC at
Level
Error
Explanation
A fatal fault in shared FC was detected.
What to do
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message content
LPAR manager detected Hardware error for Shared FC.
Level
Error
Explanation
A fatal fault in shared FC was detected.
What to do
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
for SVP access.