Connection to setup terminal

A setup terminal connected via local area network (LAN) or serial cable is initially required.
Connect a setup terminal to an external interface of a management module. See "Cable
Connection for the System Console" in Chapter 6.
For LAN connection, IP addresses shown in the table below are assigned to switch module
slots for 10 Gb Data Center Bridging (DCB) switch modules.
Network connection specifications (shipment setting)
Item
IP address
Subnet mask
For serial cable connection, select a 10 Gb DCB switch module to connect using SCO
command. See Chapter 6 > System Console Command Reference > Basic operation > SCO
Command.
Setting
switch module2: 192.168.253.37
switch module3: 192.168.253.38
switch module4: 192.168.253.39
switch module5: 192.168.253.40
255.255.255.240